Deep Freezer Service

    Deep freezer rooms — −25°C to −35°C industrial storage

    Industrial deep-freezer rooms engineered for −25°C to −35°C with thicker PUF, dual-stage refrigeration and mandatory ante room.
    • 150 mm PUF panel
    • Dual-stage / cascade refrigeration option
    • Mandatory ante room
    • DG backup recommended
    Deep freezer cold storage room at minus 30 degrees Celsius with heavy frost on walls and frozen seafood boxes neatly stacked

    Typical applications

    Frozen seafood (export grade)
    Frozen processed meat
    Ice cream (industrial holding)
    IQF storage
    Pharma & lab (controlled)

    Operating Temperature

    −25°C to −35°C

    Relative Humidity

    Not controlled

    Engineering note

    Below −30°C, cascade refrigeration or screw compressors are typical.

    01

    Technical Specifications & Construction

    Every deep freezer room we build follows the same engineering discipline — sized to your load, not picked off a brochure. Specifications below reflect typical HyperCold builds.

    Panel thickness
    150 mm
    Floor
    PUF + chequered Al + heated floor
    PUF panel density
    40 ± 2 kg/m³ (CFC-free polyurethane)
    Skin
    0.5 mm PPGL / GI pre-coated steel both sides
    Joinery
    Cam-lock with EPDM gaskets
    Refrigeration
    Daikin / Bitzer / Emerson scroll or screw
    Controls
    Carel / Danfoss digital with data-logger
    02

    How HyperCold Designs This Cold Room

    These are the design factors we lock down before quoting. Skip any of these and the project either runs hot, drinks electricity, or under-delivers on shelf life.

    Cascade refrigeration

    For temperatures below −30°C, cascade systems are more efficient than single-stage.

    Door & gasket selection

    Heated door frame to prevent gasket freeze-stick and door sealing failure.

    Site conditions

    Ambient design, condenser placement and water supply heavily affect compressor sizing.

    03

    What Drives the Project Cost

    We don't quote square-foot rates — every build is BOQ-priced. The factors below decide where your project lands within a realistic range.

    • 01Cascade vs single-stage refrigeration
    • 02Ambient design conditions
    • 03DG backup capacity
    • 04Refrigeration brand and capacity (TR)
    • 05Floor type (PUF + chequered Al vs heated)
    • 06Door type, ante room, electrical and DG backup
    • 07Civil work and site readiness (Extra)
    04

    Why Operators Choose HyperCold

    Engineered, not assembled

    Heat-load, airflow, panel thickness and refrigeration sized for your commodity and site.

    Line-item BOQ

    Transparent panel, refrigeration, accessory, installation and AMC pricing — no lump-sum surprises.

    Pan-India delivery

    Manufactured at Sirsaganj, Firozabad; installed across India with regional service support.

    Subsidy-ready DPR

    Documentation aligned to NHB, MIDH, MoFPI, AIF and state scheme norms.

    05

    Project Process — Enquiry to Handover

    1. 1

      Step 1

      Site & commodity discovery

      Capacity, commodity, temperature, ambient, power and site access.

    2. 2

      Step 2

      Heat-load & BOQ

      Engineered heat-load, panel and refrigeration sizing, line-item BOQ.

    3. 3

      Step 3

      Fabrication & dispatch

      PUF panel manufacturing at our Firozabad plant, packaged for pan-India dispatch.

    4. 4

      Step 4

      Installation & commissioning

      On-site panel erection, refrigeration installation, leak test, pull-down and handover.

    5. 5

      Step 5

      AMC & uptime

      Annual maintenance contract with response SLA and spares planning.

    06

    Scope split — what we deliver, what your site provides

    Clear scope upfront avoids the most common project-cost surprises. Items marked "subject to" are finalised after technical site evaluation.

    HyperCold scope

    • Heat-load and refrigeration sizing (BOQ-based)
    • PUF panel manufacturing at our Firozabad plant
    • Refrigeration unit supply, piping, charging and leak test
    • On-site panel erection, door fitting and commissioning
    • Control panel, sensors and data-logger (where applicable)
    • Operator handover, AMC kick-off and warranty documentation

    Client / site scope

    • Civil work — floor, walls, foundation, plinth (subject to final site inspection)
    • 3-phase electrical supply up to the project room (load to be confirmed after technical evaluation)
    • Earthing pit, MCB / RCCB at the LT panel side
    • Water supply for installation and cleaning
    • Site access — crane / hydra movement, internal pathway and unloading zone
    • Any local permissions (fire NOC, FSSAI, pollution clearance) — subject to scheme guidelines
    07

    Common mistakes we help clients avoid

    Most of these surface only after commissioning, when fixes are expensive. Catching them at quotation stage protects both shelf life and capex.

    01

    Using freezer-room specs for deep freezer

    −25°C to −35°C needs thicker PUF, stronger compressors and a different defrost strategy. A freezer-room spec will simply not pull down.

    02

    Assuming ambient design = 35°C everywhere

    Many Indian sites peak above 45°C. Sizing on a low ambient leaves the unit incapable of holding setpoint in May–June.

    03

    Under-sizing electrical supply or skipping DG backup

    Cold rooms run year-round. A weak LT supply or no DG plan turns every grid outage into a spoilage event.

    04

    Treating subsidy as a guarantee

    Subsidy eligibility depends on project type, beneficiary category, scheme notification and department verification. Plan financials independent of subsidy approval.

    08

    Reference visuals & build photos

    Indicative engineering visuals — actual build configuration depends on commodity, capacity and site.

    Deep freezer cold storage room at minus 30 degrees Celsius with heavy frost on walls and frozen seafood boxes neatly stacked
    Deep Freezer Room — engineered build by HyperCold.
    Deep freezer interior
    −25 to −30°C deep-freeze room with heated floor option.
    Industrial low-temp plant
    Screw / scroll low-temp refrigeration with subcooler.
    Condensing unit row
    Outdoor condenser plant with service walkway.
    Frozen export warehouse
    Export-grade frozen storage with data-logger and alarm.
    09

    How HyperCold Deep Freezer Room compares

    Indicative comparison between a typical local fabricator approach and an engineered HyperCold build. Final scope is confirmed after site inspection.

    Build factorTypical local fabricatorHyperCold engineered
    Sizing basisSquare-feet thumb ruleHeat-load worksheet per commodity & ambient
    Panel & skinGeneric PUF, mixed skinPPGL / GI both sides, 40 ± 2 kg/m³ PUF, cam-lock
    RefrigerationLocally sourced, no brand commitmentDaikin / Bitzer / Emerson — sized to TR
    DocumentationSingle-line quoteLine-item BOQ + DPR aligned to subsidy norms
    Controls & dataMechanical thermostatCarel / Danfoss digital with data-logger
    Handover & AMCVerbal warrantyWritten warranty, SLA-backed AMC, spares planning
    10

    Frequently Asked Questions

    Subsidies & finance that may apply

    Eligibility depends on project type, applicant category, state and current government notification. Below is indicative — verify with the official scheme portal before applying.

    MoFPI Integrated Cold Chain (PMKSY)

    Grant-in-aid for integrated pre-cooling, IQF, blast freezing, CA and reefer logistics.

    Read scheme details

    Agriculture Infrastructure Fund (AIF)

    Interest subvention and credit guarantee on bank term loans for post-harvest infrastructure.

    Read scheme details

    PMFME — Micro Food Processing

    Credit-linked subsidy for micro food processing units including small cold rooms.

    Read scheme details

    MSME & Bank Finance (CGTMSE, SIDBI, NABARD)

    Term loan and working capital options via scheduled banks, SIDBI, NABARD and cooperatives.

    Read scheme details

    Ready to scope your deep freezer room?

    Share your product, room size, and target temperature. We'll send a BOQ-priced quote with PUF, refrigeration, installation, and AMC — pan-India delivery from Sirsaganj, Firozabad.

    WhatsApp